Performance upgrades, tested before and after.
Air sealing, insulation, duct work and ventilation planned from measured test results, with the Manual J load calculated before and after the upgrades so the HVAC system is sized for the house you end up with.

Six steps to lower bills and a house that works.
This is the sequence we follow on every performance project. The goal is lower utility bills, steady humidity and a house that is safe and comfortable.
1. Test-in
Blower door (envelope leakage), duct leakage, combustion safety, room pressures, humidity and indoor air checks. This is the baseline.
2. Load calculation (before)
An ACCA Manual J load calculation using measured leakage, insulation and duct conditions instead of assumptions.
3. Upgrades
Air sealing first, then insulation, duct sealing or replacement, and ventilation, in the order that gives the most benefit for the money.
4. Test-out
The same tests repeated, so the improvement is measured, not estimated.
5. Load calculation (after) and design
Manual J re-run with the new test results, then Manual S to select equipment and Manual D to size ducts.
6. Utility review
Bills compared before and after, adjusted for weather, so you can see what the work did.
Why we calculate the load twice.
The 2021 International Residential Code requires heating and cooling equipment to be sized with ACCA Manual S, based on loads calculated with ACCA Manual J or another approved method (2021 IRC M1401.3), and duct systems to be designed with ACCA Manual D or another approved method (2021 IRC M1601.1, via Montana DLI training).
Air sealing, insulation and duct sealing reduce the heating and cooling load. If new equipment is sized to the house before the upgrades, it will be oversized for the house after them. In Houston, an oversized air conditioner short-cycles and removes less moisture, which is why a tighter house with the old-sized system can feel clammy. Running Manual J before and after, then selecting equipment with Manual S and sizing ducts with Manual D, matches the system to the improved house.
- Equipment sized for the house after upgrades
- Better humidity control from right-sized equipment
- Ducts sized for the new airflow
- Ventilation added where a tighter house needs it
How air sealing changes the cooling load.
This is a hypothetical house, not a customer project, and it uses a simplified rule of thumb rather than the full Manual J procedure. It shows the direction and rough size of the change.
Step 1 — House volume. Floor area times ceiling height: 2,200 square feet times 9 feet equals 19,800 cubic feet.
Step 2 — Leakage before (ACH50). Blower door airflow at 50 pascals times 60 minutes, divided by the house volume: 3,300 times 60 equals 198,000; 198,000 divided by 19,800 equals 10.0 air changes per hour at 50 pascals. That is a leaky house.
Step 3 — Leakage after air sealing. The test-out reads 1,980 CFM50: 1,980 times 60 equals 118,800; 118,800 divided by 19,800 equals 6.0 ACH50.
Step 4 — Estimate natural air leakage. A common rule of thumb divides CFM50 by about 20: 3,300 divided by 20 equals 165 cubic feet per minute before; 1,980 divided by 20 equals 99 after.
Step 5 — Sensible (temperature) load. 1.08 times airflow times the indoor-outdoor temperature difference. With a 20-degree difference: 1.08 times 165 times 20 equals 3,564 Btu per hour before; 1.08 times 99 times 20 equals 2,138 after.
Step 6 — Latent (moisture) load. 0.68 times airflow times the moisture difference in grains per pound. With 55 grains: 0.68 times 165 times 55 equals 6,171 Btu per hour before; 0.68 times 99 times 55 equals 3,703 after.
Step 7 — Total change. Before: 3,564 plus 6,171 equals 9,735 Btu per hour. After: 2,138 plus 3,703 equals 5,841. The reduction is 9,735 minus 5,841, or 3,894 Btu per hour. Divided by 12,000 Btu per ton, that is about 0.32 ton from air sealing alone.
What it means: in Houston, most of the saving in this example is moisture, not temperature. Sealing the house removes humid outdoor air the air conditioner would otherwise have to dry. The real Manual J uses its own infiltration method, and attic insulation and duct sealing change other parts of the load, which is why we re-run the full calculation with the test-out numbers.

Checking the bills fairly.
A hot August after the work can make bills look worse even when the house improved. We compare usage against cooling degree days, a measure of how hot the weather was, so that the before and after periods are compared on the same basis.
In words: cooling energy equals the monthly use minus the baseline use from mild months; dividing that by the month’s cooling degree days gives energy per degree day, which can be compared from one summer to the next.
ENERGY STAR estimates that sealing and insulating saves homeowners an average of 15 percent on heating and cooling costs nationally (ENERGY STAR); its methodology table shows a smaller average for Climate Zone 2, which includes Houston (ENERGY STAR methodology). Results vary by house, and we do not guarantee a specific saving.
Tightening a house changes how combustion appliances draft and how much fresh air enters. We test gas water heaters and furnaces for spillage and carbon monoxide after air sealing, and evaluate whether the house needs mechanical ventilation. See combustion safety testing.
Rated 4.9 on Google.
Real reviews from Houston homeowners and property owners. Read every review on Google or see more on our reviews page.
“Needed a plumber for a water leak emergency. Keith and his crew were here within 45 mins from calling. They met with the adjuster and had our home back to perfect within 2 months.”— Alex A., Yahoo Local review
“Keith is the owner, he is friendly, professional. Very detail-oriented. He makes sure everything is done correctly.”— Pam G., Angi review
“Very impressed by Keith’s skills and experience. He was able to identify and fix my plumbing issues, and was very honest about what needed to be fixed now, and what could wait.”— Thor Oxnard, Google review
Related services and guides
One call. Every trade. Any hour.
Plumbing, HVAC, water, fire, mold and building diagnostics — handled by one licensed Houston team since 2013.
Frequently asked.
Still unsure? Call (832) 904-9001 and talk to a licensed professional — not a call center.
Why not just buy a bigger air conditioner?
What gets done first?
Will this lower my bill?
Do I need new HVAC equipment?
Code, standard and agency references used on this page. Requirements change; confirm the edition your jurisdiction or carrier applies.
- 2021 IRC Section M1401.3: Equipment sizing per ACCA Manual S and Manual J
- Montana DLI training handout: Manual S and D under the 2021 IRC (M1601.1 duct design)
- ACCA: Manual J, Manual S and Manual D residential design standards
- ENERGY STAR: Why seal and insulate
- ENERGY STAR: Air sealing and insulation savings methodology
- Building Performance Institute (BPI)