Blower door testing for code, comfort and moisture.

Calibrated air-leakage testing for new homes, additions and existing homes, with leak-finding and a written report you can hand to your builder or inspector.

BPI Building Analyst Professional & Technician — Keith Lamb, BPI ID 5077142. HVAC work under TDLR TACLA153255E.
Infrared camera scanning a room with a blower door installed in the doorway
What It Measures

How tight is your house?

A blower door uses a calibrated fan in an exterior doorway to depressurize the home, usually to 50 pascals, about the pressure of a 20 mph wind on all sides at once. The fan flow at that pressure is CFM50. Divided by the house volume and converted to an hourly rate, it becomes air changes per hour at 50 pascals, or ACH50.

In Houston, envelope leakage is not just an energy issue. Hot, humid air drawn through walls and ceilings can drive condensation, musty odors and humidity complaints.

  • Pre-drywall and final pre-tests for builders
  • Leak location with smoke and thermal imaging
  • Before and after air-sealing comparison
  • Inputs for Manual J sizing and ventilation design
  • Humidity and odor investigations
From Our Jobs

Blower door testing in Houston homes.

With the house depressurized, infrared imaging and smoke show exactly where air is leaking in.

Worked Example

How ACH50 is calculated.

The 2021 IECC uses ACH50 for the Climate Zone 2 limit, so it is the number most Houston builders and buyers ask about.

Formula in words: ACH50 equals CFM50 multiplied by 60 minutes per hour, divided by the conditioned volume in cubic feet.

Step 1. Volume: 2,000 square feet of conditioned floor area times a 9-foot average ceiling equals 18,000 cubic feet.

Step 2. The blower door measures 1,500 CFM50.

Step 3. 1,500 × 60 = 90,000 cubic feet per hour.

Step 4. 90,000 ÷ 18,000 = 5.0 ACH50.

Meaning. That result sits exactly at the 2021 IECC prescriptive limit of 5.0 ACH50 for Climate Zone 2. The same house at 1,200 CFM50 would test at 4.0 ACH50.

Example values are illustrative. Your report states the measured volume, CFM50, test conditions and result.

Code Limits

2021 IECC air leakage requirements.

Houston adopted the 2021 IECC with amendments, effective January 1, 2024.

ItemRequirement
Climate Zone 2 prescriptive limit5.0 ACH50 or less
Maximum on any compliance path5.0 ACH50 or 0.28 CFM50 per square foot of enclosure area
Test standardANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827 at 50 pascals
ReportWritten and signed by the party conducting the test

Sources: 2021 IECC R402.4; City of Houston Ordinance 2023-907. See energy code testing for Houston’s third-party tester requirement.

Client Correspondence

Rated 4.9 on Google.

Real reviews from Houston homeowners and property owners. Read every review on Google or see more on our reviews page.

★★★★★
“Needed a plumber for a water leak emergency. Keith and his crew were here within 45 mins from calling. They met with the adjuster and had our home back to perfect within 2 months.”
— Alex A., Yahoo Local review
★★★★★
“Keith is the owner, he is friendly, professional. Very detail-oriented. He makes sure everything is done correctly.”
— Pam G., Angi review
★★★★★
“Very impressed by Keith’s skills and experience. He was able to identify and fix my plumbing issues, and was very honest about what needed to be fixed now, and what could wait.”
— Thor Oxnard, Google review
Houston · 24 Hours

One call. Every trade. Any hour.

Plumbing, HVAC, water, fire, mold and building diagnostics — handled by one licensed Houston team since 2013.

(832) 904-9001
Call NowRequest Service
616 W Virginia St, Houston, TX 77076
Questions, Answered

Frequently asked.

Still unsure? Call (832) 904-9001 and talk to a licensed professional — not a call center.

What air-leakage limit applies to my house?
New homes in Houston are held to the 2021 IECC with local amendments; the Climate Zone 2 prescriptive limit is 5.0 ACH50. Existing homes are not required to meet it, but the number shows where you stand.
Will the test damage anything?
No. The test simply moves air. We secure fireplaces and combustion appliances before testing.
How long does it take?
Setup and testing usually take about an hour. Leak-finding adds time depending on the house.
Can a house be too tight?
A tight house needs planned mechanical ventilation. The 2021 IECC and IRC address ventilation for that reason. We include ventilation in our recommendations.
Call 24/7Request Service